SAF OPAL Ethernet IP Interface MS6 SERIES Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Sítě SAF OPAL Ethernet IP Interface MS6 SERIES. Opal Pro AB Ethernet IP Interface 1.00 Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 14
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Opal Pro to Mod TCP
Page 1
Opal Pro MS6 SERIES
AB Ethernet IP Interface Users Manual
Revision 1.00
Zobrazit stránku 0
1 2 3 4 5 6 ... 13 14

Shrnutí obsahu

Strany 1 - Opal Pro MS6 SERIES

Opal Pro to Mod TCP Page 1 Opal Pro MS6 SERIES AB Ethernet IP Interface Users Manual Revision 1.00

Strany 2

Opal Pro to Mod TCP Page 10 I/O Configuration The Opal Pro supports 4 input words and 51 output words. Their description is as follows: Input Word

Strany 3 - FOR YOUR SAFETY

Opal Pro to Mod TCP Page 11 Output Words (Polled) AB Ethernet IP Name Description Bit 0 – Ready to Run (drive is enable and has 3 phase power) Bit

Strany 4

Opal Pro to Mod TCP Page 12 Relay Status Status of the Relay Outputs Bit 0 – Running Bit 1 – By-Pass Bit 2 – Shorted SCR Bit 3 – Reverse 1.07

Strany 5 - Table of Contents

Opal Pro to Mod TCP Page 13 12.01 Input Word 27 Analog Output 16 = Current Reference 17 = Current Feedback 18 = Overload level 19 = Phase Angle 13.0

Strany 6

Opal Pro to Mod TCP Page 14 NOTE: The Opal Pro must have firmware version 1.70 or higher.

Strany 7 - LED Indicators

Opal Pro to Mod TCP Page 2

Strany 8 - Opal Pro Parameter Settings

Opal Pro to Mod TCP Page 3 FOR YOUR SAFETY Only qualified personnel should install this equipment, after first reading and understanding a

Strany 9

Opal Pro to Mod TCP Page 4

Strany 10 - I/O Configuration

Opal Pro to Mod TCP Page 5 Table of Contents INTRODUCTION ...

Strany 11 - Page 11

Opal Pro to Mod TCP Page 6 Opal Pro to Mod TCP Introduction The Opal Pro can be monitored and controlled over an Ethernet communication network using

Strany 12 - Page 12

Opal Pro to Mod TCP Page 7 LED Indicators Two bi-colour (red/green) LED indicators are mounted beside the network connector. The upper LED indicates

Strany 13 - Page 13

Opal Pro to Mod TCP Page 8 Opal Pro Parameter Settings The parameters in the Opal Pro used to configure the Ehernet interface card (group 14) are onl

Strany 14 - 1.70 or higher

Opal Pro to Mod TCP Page 9 15.04 Comm Fault Enable Disable Enable – Opal Pro trips out on a communication fault Disable – Nothing happens on a commu

Komentáře k této Příručce

Žádné komentáře